RETENTION AND DETENTION

Retention and detention systems manage stormwater on your site. Retention systems hold the water permanently, to soak into the ground or be reused. Detention systems temporarily store stormwater and release it slowly so the network isn’t overwhelmed in heavy rain.

If you can’t see it, it’s easy to forget it. Unfortunately, sediment build-up is the largest cause of retention and detention system failure. As the sediment builds, storage is lost, outlets block, and the system stops doing the job it was designed and consented to do.

Most manufacturers recommend inspection at least once a year and after major storms, and the specifics are in your operation and maintenance manual. If you’re not sure where to start, Auckland Council has a practice note on stormwater tanks which is a good place to begin.

Getting to these systems is rarely easy. Access is often through small risers or manholes, and some need confined space entry. That’s where we come in.

RETENTION AND DETENTION SERVICES

Sediment removal & tank cleaning

Sediment and debris gradually build up inside retention and detention systems, reducing the space available to store stormwater. We use vacuum loading and cleaning equipment to remove accumulated silt, sludge and debris, helping restore the system’s storage capacity.

Access can be tight, and some systems require specialist confined space procedures. We’ll work out what’s involved based on the tank design and site access.

Inlet, outlet & flow control maintenance

A tank can have plenty of storage space but still fail to work properly if the inlet, outlet or flow controls are blocked. Screens, orifices and outlet pipes can all collect debris, restricting the flow of water through the system.

We can clear built-up debris and blockages around accessible components, helping stormwater enter and discharge at the rate the system was designed for. If we find damaged or faulty components, we’ll let you know what needs attention.

Upstream stormwater device maintenance

The best way to reduce sediment build-up in your tank is to catch as much of it as possible before it gets there. Cesspits and other pretreatment devices help collect sediment, litter and debris before it enters the main stormwater system.

We can clean out these devices and remove the material they’ve collected, helping keep sediment out of your storage tanks and the wider stormwater system.

Give us a call with some details about your system. If you have as-built drawings or a maintenance manual, these are helpful too.

“We had a stormwater detention system to sort out and weren't really sure where to start. Enviro Water talked us through what was needed and helped get the work moving. No fuss, no mucking around - just good, practical advice.”
Deon Kennedy, Tauranga